3
Ensure that the administrative state of the port is Admin Up. If it is Up, then toggle the
administrative state from UP-->DOWN-->UP.
...................................................................................................................................................................................................
4
If... Then...
no active traffic is present on the system remove the fiber from the receive port where
the SDEG-O is raised and measure the optical
power.
the optical power is below the required
threshold for the type of pluggable module
installed
using the standard optical fiber jumper
cleaning procedure, clean the fiber, and
measure the power again.
the optical power is within the required limits clean the receive connector on the card. If the
SDEG-O condition is still present, the problem
may be with the card.
...................................................................................................................................................................................................
5
Perform a warm reset of the card exhibiting the Loss of Frame.
CLI config card card type shelf slot reset warm
WEBUI Select the card, click the Reboot tab, select Warm Reboot >Submit.
...................................................................................................................................................................................................
6
Perform a cold reset of the card exhibiting the Loss of Frame.
CLI config card card_type shelf slot reset cold
WEBUI Select the card, click the Reboot tab, select Cold Reboot >Submit.
Note: Refer to Caution at the beginning of this procedure.
...................................................................................................................................................................................................
7
Reseat the card. Refer to “Reseating a Card” (p. 3-19).
...................................................................................................................................................................................................
8
Replace the OSC SFP located inside the amplifier. See “Replacing an SFP Module”
(p. 3-27). Follow the return and repair process in the Customer and Product Support guide
to
return the faulty pluggable module to an authorized repair center for replacement.
Trouble-clearing procedures
SDEG-O
SDEG-O (SUPVY Signal Degrade)
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
2-290
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011