SWEQPT (Protection Switching Equipment Failure)
This condition indicates a problem on the mate card.
Severity Minor
Service affecting? No
Applicability 112SCA1, 112SCX10, 11DPE12E, 11DPM12, 11STAR,
11STMM10, 11STGE12, 43SCX4, 43STA1P, 43STX4, 43STX4P
Corrective Action
NOTICE
Service-disruption hazard
A cold reset, reseat, or replacement of a card is service impacting if the card is currently
carrying services. To determine if any services are currently carried over a card, perform
the procedure “Reseating a Card” (p. 3-19).
If
there are services currently carried over the card, it may be best to wait for a
maintenance window before resetting, replacing, or reseating the card.
At the end of each step wait to see if the fault clears. If not, continue with the next step.
...................................................................................................................................................................................................
1
Determine if there are any hardware or software failure alarms for the transponder card
that is inactive and providing protection for the working one. Based on the information
presented, determine the cause of the failure and resolve that issue first using the
appropriate corrective action(s).
...................................................................................................................................................................................................
2
Perform a warm reset of the card of the mate transponder card.
CLI config card card type shelf slot reset warm
WEBUI Select the card, click the Reboot tab, select Warm Reboot >Submit.
...................................................................................................................................................................................................
3
Perform a cold reset of the card of the mate transponder card.
CLI config card card_type shelf slot reset cold
WEBUI Select the card, click the Reboot tab, select Cold Reboot >Submit.