SYNCOOS (Timing reference failed--system going into
holdover)
Corrective Action
...................................................................................................................................................................................................
1
Check the reference status.
CLI show card 11dpe12e
shelf/slot
synce lineref
{1-4}
WEBUI Select the 11DPE12E card in the Equipment Tree.
Select LINEREF {1-4}.
SYNREFFAIL
SYNREFFAIL (Timing reference failed, (not Protected or
Protection not Available))
The OT port has detected an SYNCREFFAIL at the LINEREF layer. A LINEREF detects
SYNCREFFAIL when the timing reference failed, (not Protected or Protection not
Available).
Severity Minor
Service affecting? No
Applicability LINEREFSYS
Corrective Action
...................................................................................................................................................................................................
1
Check the timing reference quality and priority.
CLI show card 11dpe12e
shelf/slot
synce lineref
{1-4}
WEBUI Select the 11DPE12E card in the Equipment Tree.
Select LINEREF {1-4}.
Trouble-clearing procedures
SYNCOOS
SYNCOOS (Timing reference failed--system going into
holdover)
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
2-318
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
E ND OF STEPS
...................................................................................................................................................................................................