Viewing PoE Power Supply Status Managing Power over Ethernet (PoE)
page 6-4 OmniSwitch 6450 Hardware Users Guide September 2015
Viewing PoE Power Supply Status
To view the current status of power supplies installed, use the show power command, as shown below:
-> show power
Slot PS Wattage Type Status Location
----+----+---------+------+-----------+----------
1 1 900 AC UP Internal
1 2 900 AC UP External
For detailed information on the show power command output, refer to the OmniSwitch 6250/6450 CLI
Reference Guide.
Configuring Power over Ethernet Parameters
Power over Ethernet Defaults
The following table lists the defaults for PoE configuration:
Understanding and Modifying the Default Settings
The sections below provide information on each of the key components within the Power over Ethernet
software. They include information on PoE-related CLI commands. For detailed information on PoE-
related commands, refer to the OmniSwitch 6250/6450 CLI Reference Guide.
Note. PoE units support different wattage power supplies. If an unsupported power supply is used, a
console message and a trap are generated.
Parameter Description Command(s) Default Value/Comments
PoE operational status lanpower start or lanpower stop Disabled
Total power available to a port lanpower power Varies depending on chassis and
power supply type. For more
information, refer to product
specifications in Chapter 3.
Total PoE power available to an
entire chassis
lanpower maxpower Varies depending on chassis and
power supply type. For more
information, refer to product
specifications in Chapter 3.
Power priority level for a port lanpower priority Low
Priority disconnect status lanpower priority-disconnect Enabled