Getting Started Your First Login Session
OmniSwitch 6350 Hardware Users Guide September 2015 page 2-9
Setting Optional Parameters
Specifying an Administrative Contact
An administrative contact is the person or department in charge of the switch. If a contact is specified, users 
can easily find the appropriate network administrator if they have questions or comments about the switch.
To specify an administrative contact, use the system contact command.
Specifying a System Name
The system name is a simple, user-defined text description for the switch. 
To specify a system name, use the system name command.
Specifying the Switch’s Location
It is recommended that you use a physical labeling system for locating and identifying your switch(es). 
Examples include placing a sticker or placard with a unique identifier (e.g., the switch’s default IP address) on 
each chassis.
However, if no labeling system has been implemented or if you need to determine a switch’s location from a 
remote site, entering a system location can be very useful.
To specify a system location, use the system location command.
Viewing Your Changes
To view your current changes, enter show system at the CLI prompt.
Saving Your Changes
Once you have configured this basic switch information, save your changes by entering write memory at the 
CLI command prompt.