117
Bright. The Standby Screen shows dark
characters on a light background.
Suited for use in bright/day-time
conditions.
Invert. The Standby Screen shows light
characters on a dark background.
Suited for low light conditions.
Antimicrobial (requires Clock to
be set)
Hot Water Boost will automatically
activate at 02:00 every morning. This
further reduces the risk of Legionella bacteria.
Circulation Pump
Select which circulation pump to use
for the central heating, depending on
what pumps are installed.
(Your caravan is fitted with Pump Manual 12V)
Pump Manual 12 V. For the 12 V
inline circulation pump with manual
5-speed dial.
Pump Remote 12 V. For the
remote-controlled 12 V inline
circulation pump. Pump speed can
also be set. Speed 2 is
recommended. Speed 4–5 should
only be used prior to bleeding the
system of air.
Optional Pump 12 V. For the
optional 12 V circulation pump in
the expansion tank.
Pump 230 V. For the 230 V inline
circulation pump.
Auto. Automatically selects the
230 V pump when a 230 V supply
is detected, or the optional 12 V
pump when only 12 V supply is
available.
Pump mode can also be set.
Cont. The pump is continuously active. This
will reduce the hot water supply. For testing
the circulation pump in the summer, if room
temperature exceeds 30 °C.
Thermo. The pump is controlled by the room
thermostat.
External Switch
Allows you to use a third party,
external switch to start up and
shutdown the boiler. When the
external switch starts the boiler, it will provide
heating using the last saved settings. Once
External Switch is enabled, the system should
be shut down by pressing the Power button.
The external switch then takes control of the
boiler.
Ext. When a circuit is made at X18 on the
boiler, the boiler is started. When the circuit
is broken, the boiler shuts down. For use
with a third party rocker or toggle switch,
or compatible telematics systems. NB: The
Alde 3010-219 adaptor lead is available for
connecting an external switch.
230V. When 230 V is detected, the boiler
is started. When 230 V supply is lost, the
boiler shuts down. No additional accessories
required.
Off. External Switch is disabled.
TIP: Hiring out a vehicle? Your customers
can operate the central heating/hot water
with a convenient wall switch, whilst
the control panel is fitted in a locked
maintenance cupboard with a discrete room
temperature sensor. On-off, no hassles.
Language
Select English, French or German
language. NB: The Service Menu is
English language only.
Load Monitor
If an Alde 3010-246 load monitor is
installed, this allows you to set an
amp limit from 5–17 A for the vehicle’s
230 V power. If the current drawn by the
vehicle exceeds the amp limit, the boiler will
automatically reduce power.
This helps avoid tripping the circuit breakers
on the electric hook up. The load monitor can
be disabled by selecting “Off”.