Maintenance
Manualcleaningofopenedunits
Caution!
Neverusehydrochloricacidwithstainlesssteelplates.Waterofmorethan330ppmCl
maynotbeusedforthepreparationofcleaningsolutions.
Itisveryimportantthatcarryingbarsandsupportcolumnsinaluminiumareprotected
againstchemicals.
Note!
Becarefulnottodamagethegasketduringmanualcleaning.
Warning!
Useproperprotectiveequipment,suchassafetyboots,safetyglovesandeyeprotection,
whenusingthecleaningagents.
Warning!
Corrosivecleaningliquidscancauseseriousinjuriestoskinandeyes!
Depositsremovablewithwaterandbrush
PlatesdonotneedtoberemovedfromthePHEduringcleaning.
Step1
Startcleaningwhentheheatingsurfaceisstillwetandtheplates
arehangingintheframe.
Step2
Removedepositsusingasoftbrushandrunningwater.
Step3
Rinsewithwaterusingahighpressurehose.
DocumentIDLanguageEdition
24InstructionManual-PlateHeatExchangers3490010217EN2014-11