EasyManua.ls Logo

Alfa level M3 - Regasketing

Default Icon
30 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintenance
Regasketing
TheproceduresbelowregardsFieldgaskets,RinggasketsandEndgaskets
Note!
Beforeremovingtheoldgasketscheckhowitisattached.
Clip-on/ClipGrip
Step1
OpenthePHE,refertoonpageandremovetheplatethatis
tohaveanewgasket.
Note!
BeforeopeningthePHEcheckthewarrantyconditions.If
inanydoubt,contactanAlfaLavalsalesrepresentative.
Referto“Warrantyconditions”onpage4.
Step2
Removetheoldgasket.
Step3
Assurethatallsealingsurfacesaredry,cleanandfreeofforeign
mattersuchasfat,greaseorsimilar.
Step4
Checkthegasketandremoverubberresidualbeforeattachingit.
Note!
Especiallytheendplategasket!!
Step5
AttachtheClip-on/ClipGripgaskettotheplate.Slipthegasket
tabsundertheedgeoftheplate.
Note!
Makesurethetwogasketprongsareincorrectposition.
ClipGrip
Step6
Repeattheprocedureuntilallplatesthatisneededtobe
regasketedisdone.ClosethePHEaccordingtoClosingon
page26.
DocumentIDLanguageEdition
3490010217EN2014-11InstructionManual-PlateHeatExchangers29
EN