EasyManua.ls Logo

Alfa level M3 - Closing, Regasketing, and Testing

Default Icon
30 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintenance
Closing
FollowtheinstructionsbelowtoensurethatthePHEwillbeproperlyclosed.
ForidentifyingboltrefertoBoltcongurationonpage20
Step1
Checkthatallthesealingsurfacesareclean.
Step2
Brushthethreadsoftheboltsclean,usingasteelwirebrushor
theAlfaLavalthreadcleaner.Lubricatethethreadswithathin
layerofgrease,e.g.Gleitmo800orequivalent.
Step3
Attachgaskettotheplatesorcheckthatallthegasketsare
properlyattached.
Note!
Ifthegasketiswronglypositioned,itwillshowbythe
factthatitrisesoutofthegasketgrooveorthatitis
positionedoutsidethegroove.
Step4
Iftheplateshavebeenremovedinsertthetheminalternate
directionsandwiththegasketsturnedtowardstheframeplate
orpressureplateasspeciedontheplatehanginglist.Usethe
markedlinethatwasdonewhenthePHEwasopened,referto
Step7in“Opening”onpage20.
Step5
Iftheplatepackhasbeenmarkedontheoutside,checkthis
Step7in“”onpage20.
Iftheplatesarecorrectlyassembled(A/B/A/Betc.),theedges
forma“honeycomb”pattern,seepicture.
DocumentIDLanguageEdition
26InstructionManual-PlateHeatExchangers3490010217EN2014-11