Chapter 4 Bulletin 290E/291E/294E Programmable Parameters
OutNetIdleValue
This parameter determines the state that
starter outputs assumes when the
network is idle and Parameter 56
(OutNetIdleState) is set to 0.
0 = OFF
1 = ON
Parameter Number 57
Access Rule GET
Data Type BOOL
Group User I/O Config.
Units
Minimum Value 0
Maximum Value 1
Default Value 0
Input00Function
This parameter determines the special
function for User Input 0:
0 = NoFunction
1 = FaultReset
2 = MotionDisable
3 = ForceSnapShot
4 = UserFault
5 = BrakeRelease
These choices are level sensitive. All
others are edge sensitive
Parameter Number 58
Access Rule GET/SET
Data Type USINT
Group User I/O Config.
Units
Minimum Value 0
Maximum Value 4
Default Value 0
Input01Function
This parameter determines the special
function for User Input 1:
0 = NoFunction
1 = FaultReset
2 = MotionDisable
3 = ForceSnapShot
4 = UserFault
5 = BrakeRelease
These choices are level sensitive. All
others are edge sensitive
Parameter Number 59
Access Rule GET/SET
Data Type USINT
Group User I/O Config.
Units
Minimum Value 0
Maximum Value 4
Default Value 0
Input02Function
This parameter determines the special
function for User Input 2:
0 = NoFunction
1 = FaultReset
2 = MotionDisable
3 = ForceSnapShot
4 = UserFault
5 = BrakeRelease
These choices are level sensitive. All
others are edge sensitive
Parameter Number 60
Access Rule GET/SET
Data Type USINT
Group User I/O Config.
Units
Minimum Value 0
Maximum Value 4
Default Value 0