102 Rockwell Automation Publication 20A-UM001N-EN-P - July 2013
Appendix B HIM Overview
Menu Structure
Diagnostics Menu
When a fault trips the drive, use this menu to access detailed data about the drive.
Parameter Menu
Refer to Viewing and Editing Parameters on page 103.
Option Description
Faults View fault queue or fault information, clear faults or reset drive.
Status Info View parameters that display status information about the drive.
Device Version View the firmware revision and hardware series of components.
HIM Version View the firmware revision and hardware series of the HIM.
User
Display
Diagnostics
Main Menu:
Start-Up
Esc Sel
Esc
Faults
Status Info
Device Items
Device Version
HIM Version
Fault Info
View Fault Queue
Clear Faults
Clr Fault Queue
Reset Device
Drive Status 1
Drive Status 2
Drive Alarm 1
Drive Alarm 2
Speed Ref Source
Start Inhibits
Last Stop Source
Dig In Status
Dig Out Status
Drive Temp
Drive OL Count
Motor OL Count
LCD Module Product Data
LCD HIM Control Board
Keyboard – Numeric
Continue
Start Over
Press
Press
Press
to move between menu items
Press to select how to view parameters
to select a menu item
to move 1 level back in menu
Memory Storage
HIM CopyCat
Device User Sets
Reset To Defaults
Device -> HIM
Device <- HIM
Delete HIM Set
Drive User Set:
Save To User Set
Load Frm Usr Set
Active Set Name
Introduction
PowerFlex 70 EC
Connected DPI Devices
Device Select
Parameter
Preferences
Device Identity
Change Password
User Dspy Lines
User Dspy Time
User Dspy Video
Reset User Dspy
Contrast
FGP: File
File 1 Name
File 2 Name
File 3 Name
FGP: Group
Group 1 Name
Group 2 Name
Group 3 Name
FGP: Parameter
Parameter Name
Parameter Name
Parameter Name
Basic
Advanced
Reserved
Param Access Lvl
File-Group-Par
Numbered List
Changed Params
ALT
Sel
ALT
Sel
Value Screen
PowerFlex 70 EC
Product Data
Main Control Board
Power Unit Board
Complete Steps:
1.
SC:
Input Voltage
EC:
Motor Control
2. Motor Dat/Ramp
3. Motor Tests
4. Speed Limits
5.
SC:
Speed Control
EC:
Speed/Freq
6. Strt/Stop/I/O
7.
SC:
Done/Exit
EC:
Application
8.
EC:
Done/Exit
(1)
Esc
Make a selection:
Abort
Backup
Resume
Start-Up Menu
Make a selection:
1. Flying Start
2. Auto Restart
3. Done
Make a selection:
1. SMART
2. Basic
3. Detailed
4. More Info
(1)
Important: Done/Exit must be selected upon completion of the Start-Up routine
in order for any Start Up/Autotune data to be saved.
View selected through

Other manuals for Allen-Bradley PowerFlex 70

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allen-Bradley PowerFlex 70 and is the answer not in the manual?

Allen-Bradley PowerFlex 70 Specifications

General IconGeneral
Input Voltage200-240V AC, 380-480V AC, 500-600V AC
Frequency Range0 - 400 Hz
Humidity5% to 95% non-condensing
Output Voltage0 to Input Voltage
Control MethodsSensorless Vector Control
CommunicationsEthernet/IP, DeviceNet, ControlNet
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overtemperature, Ground Fault
Operating Temperature0°C to 50°C (32°F to 122°F)
Storage Temperature-40°C to 70°C (-40°F to 158°F)
Enclosure RatingIP20, NEMA Type 1