4 Rockwell Automation Publication 1783-IN013B-EN-P - December 2019
Stratix 5800 Ethernet Managed Switches
ATTENTION: (Catalog numbers 1783-MMS10 Series A, 1783-MMS10B Series A, 1783-MMS10R Series A, 1783-MMS10ER Series A, 1783-MMS10 Series B,
1783-MMS10E Series B, 1783-MMS10B Series B, 1783-MMS10BE Series B, 1783-MMS10R Series B, 1783-MMS10ER Series B, 1783-MMS10EA Series B,
1783-MMS10EAR Series B). This equipment is certified for use only within the surrounding air temperature range of 0…60 °C (32…140 °F). The equipment
must not be used outside of this range.
ATTENTION: Use only a soft dry anti-static cloth to wipe down equipment. Do not use any cleaning agents.
European Hazardous Location Approval
The following applies to products marked G:
Are Equipment Group II, Equipment Category 3, and comply with the Essential Health and Safety Requirements relating to the design and construction of such equipment
given in Annex II to Directive 2014/34/EU. See the EC Declaration of Conformity at http://www.rockwellautomation.com/global/certification/overview for details.
(Catalog numbers 1783-MMS10 Series A, 1783-MMS10E Series A, 1783-MMS10B Series A, 1783-MMS10BE Series A, 1783-MMS10R Series A, 1783-MMS10ER Series A). The
type of protection for base and standard switches is Ex nA nC IIC T4 Gc according to EN 60079-15.
(Catalog numbers 1783-MMS10 Series B, 1783-MMS10E Series B, 1783-MMS10B Series B, 1783-MMS10BE Series B, 1783-MMS10R Series B, 1783-MMS10ER Series B
1783-MMS10EA Series B, 1783-MMS10EAR Series B). The type of protection for base and standard switches is Ex nA IIC T4 Gc according to EN 60079-15.
(Catalog numbers 1783-MMX8T Series A, 1783-MMX8E Series A, 1783-MMX8EA Series A, 1783-MMX8S Series A, 1783-MMX8SA Series A,1783-MMX6T2S Series A,
1783-MMX16T Series A, 1783-MMX16E Series A, 1783-MMX14T2S Series A). The type of protection for expansion modules is Ex nA IIC T4 Gc according to EN 60079-15.
Comply to Standards <EN 60079-0:2012, EN 60079-15:2010>, reference certificate number DEMKO 19 ATEX 2207X.
Are intended for use in areas in which explosive atmospheres caused by gases, vapors, mists, or air are unlikely to occur, or are likely to occur only infrequently and for short
periods. Such locations correspond to Zone 2 classification according to ATEX directive 2014/34/EU.
Special Conditions for Safe Use
WARNING:
This equipment is not resistant to sunlight or other sources of UV radiation.
This equipment shall be mounted in an ATEX Zone 2 certified enclosure with a minimum ingress protection rating of at least IP54 (in accordance with EN
60079-15) and used in an environment of not more than Pollution Degree 2 (as defined in EN 60664-1) when applied in Zone 2 environments. The enclosure
must be accessible only by the use of a tool.
This equipment shall be used within its specified ratings defined by Rockwell Automation.
Provision shall be made to prevent the rated voltage from being exceeded by transient disturbances of more than 140% of the peak rated voltage when
applied in Zone 2 environments.
The instructions in the user manual shall be observed.
Secure any external connections that mate to this equipment by using screws, sliding latches, threaded connectors, or other means provided with this
product.
Do not disconnect equipment unless power has been removed or the area is known to be nonhazardous.