AM81687-A
Original Instructions – English
27
Fault finding & Flash codes
The following table gives checks and actions that you can perform if your machine does not
operate correctly. If these do not identify/remedy the problem, contact your service agent.
The isolation key is not inserted
The battery is not fully inserted
The battery is not charged
Speed control lever is in slow position
Cylinder mode switch is in backlap position
2 actions required to start cylinder
Insert isolation key & turn on so RED LED illuminates
Make sure the battery clicks into place
Charge the battery
Move lever to fast position
Select either cylinder fast or slow mode
Press safety button and squeeze bale bar
Machine functions
intermittently or
stops during use
Load on motors too high causing current limit to
be triggered.
Battery too hot – RED LED flashes on battery
Battery has discharged
Raise height of cut, reduce depth of cultivation task,
reduce forward speed.
Allow batteries to cool. Raise height of cut, reduce
depth of cultivation task, reduce forward speed.
Charge the battery
Machine leaves
ragged finish
Cutting blade blunt
Blades off cut
Grass too high/dense
Cylinder running in reverse
Contact service agent
Adjust blades
Raise height of cut
Turn cylinder mode switch to forwards direction
Height of cut too low
Blades adjusted too tight
Forward speed too fast for task
Increase height of cut
Adjust blades
Reduce forwards speed
Cutting blade not
rotating
Cutting blade obstructed
Blades too tight
Cutting blade damaged
Belt slipping or damaged
Clear obstruction
Slacken off blade adjuster screws
Contact service agent
Contact service agent
Land drive does not
engage
Speed control lever is in slow position
Move lever to fast position
Excessive
vibration/noise
Cutting blade damaged
Cutting blades not adjusted evenly
Contact service agent
Adjust blades
Mowing in wet conditions
Motor speed too fast/slow
Allow grass to dry, use faster speed
Increase/decrease motor speed
Cylinder will only
restart if the key
switch is cycled on
and off
No battery in right hand dock
7.5A fast blow regen fuse blown
Make sure a fully charged battery is the right hand
dock
Check fuses