13
6 Memory
6.1 Memory management
The AFX-110 can store up to 3000 IDs, each associated with a time/date stamp, in its internal memory
and transmit them to a personal computer via an USB cable or wirelessly using Bluetooth
®
.
6.2 Download Memory
1. When memory feature is enabled, the animal identification codes can be downloaded
from reader.
2. Click on “Read Memory” button to download the memory from the reader.
3. Export the ID code list to Excel by clicking on “Export to Excel” button.
4. Once finished, you can click on “Clear memory” to erase animal identification codes
stored in the reader.
6.3 Temperature measurement
The AFX-110 can read and display the Microchip Temperature when reading microchips with
temperature sensing
2
implants from Allflex or Destron Fearing.
The Microchip Temperature is displayed above the microchip number as shown in picture below.
To activate the option, enable it in the menu “general settings”
2
Microchip Temperature™ range is from 33ºC (91.4ºF) to 43ºC (109.4ºF). If the temperature is below or above this range, it will display
“TEMP BELOW RANGE” OR “TEMP ABOVE RANGE”.
982000351249512
10:49AM
FDX-B
38. C
Date/Time
Language
Buttons
Load defaults
General settings
>
>
>
>
<< Back
Vibration
Buzzer
Temperature