Water Connections
Specification Model Requirement
Water inlet connection size, in. BSP 7.5 kg - 35 kg /
20 lb - 80 lb /
75 L - 332 L
3/4
52 kg /
120 lb /
520 L /
1
Recommended pressure, PSI [bar] All 44-73 [3-5]
Inlet flow capacity per inlet (standard
pressure), gal/min [l/min.]
7.5 kg - 24 kg /
20 lb - 55 lb /
75 L - 240 L
5.28 [20]
Inlet flow capacity per inlet,
gal/min at 60 PSI [l/min. at 4 bar
]
18 kg - 28 kg /
40 lb - 70 lb /
180 L - 280 L*
34.88 [133]
Inlet flow capacity per inlet,
gal/min at 60 PSI [l/min. at 4 bar]
35 kg /
80 lb /
332 L
15.59 [59]
Inlet flow capacity per inlet,
gal/min at 60 PSI [l/min. at 4 bar]
52 kg /
120 lb /
520 L
96.68 [366]
* 18 kg - 24 kg / 40 lb - 55 lb / 180 L - 240 L -optional
Table 13
Suitable air cushions (risers) should be installed in supply lines to
prevent “hammering.”
Alliance Laundry Systems, LLC ranges of front loading commer-
cial clothes washing machines have solenoid valves at the inlets.
The machines are supplied with approved inlet hoses.
Installation
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
44 Part No. D1599ENR16