Single Drop Timer
Part No. 70458301ENR7
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 105
Cool Down Per Cycle (in minutes)
Cool Down Switch Number
Cycle Reset Switch Number
1 (factory default) OFF OFF
ON
3 ON
Table 29 Models Starting Serial No. 0909xxxxx
Total Cycle Time = Heat Time + Cool Down Time
Topoffs
Any time the control receives a coin drop pulse during a cycle
it will add the programmed dry time to the time currently
remaining in the cycle. The maximum cycle time is 99 minutes,
the control will not add time beyond 99 minutes. The cool down
time will not change.
If the control receives a coin drop pulse during cool down the
IN USE LED will flash briefly to indicate the coin input, the
machine will exit cool down and it will start heating. The cycle
time will be equal to the programmed dry time.
Temperature Selector Switch
For five minutes after the control is powered up, there is a
diagnostic feature that allows the temperature selector switches
to be tested.
When the temperature selector is changed, the new setting is
displayed by flashing the IN USE LED as follows:
High/Normal 4 flashes
Medium/PP 3 flashes
Low/Delicate 2 flashes
No Heat 1 flash
NOTE: To change dipswitch settings refer to
Dipswitch Settings section.
To Program a Short Test Cycle
1. Unplug machine power cord.
2. Write down machine control dip switch settings, then set
them all to the off position. Refer to Figure 28 .
3. Plug machine in and start a cycle.
NOTE: With all control dip switches off, the total
cycle time will be 2 minutes long (1 minute of heat
and 1 minute of cool down).
4. Once all testing is complete, unplug machine and re-set dip
switches to their original settings.
5. Plug machine in.
Figure 28