Installation/Operation/Maintenance
Tumble Dryers
120 Pound (55 Kilogram) Capacity
170 Pound (77 Kilogram) Capacity
200 Pound (90 Kilogram) Capacity
Starting Serial No. 0907003062
Refer to Page 8 for Model Identification
TMB1268C_SVG
Original Instructions
Keep These Instructions for Future Reference.
(If this machine changes ownership, this manual must accompany machine.)
www.alliancelaundry.com
Part No. 70458101ENR10
August 2015

Table of Contents

Other manuals for Alliance Laundry Systems CA170L

Questions and Answers

  • M
    Mrs. Kristine Graves DDSAug 10, 2025
    What to do if Alliance Laundry Systems Dryer control is in lockout mode?
    • M
      Matthew DorseyAug 10, 2025
      If the control is in lockout mode, a manual reset is needed. You can reset it by pushing the red lockout button or using the front end control.
  • J
    Jonathan KingAug 16, 2025
    What to do if Alliance Laundry Systems Dryer has valve on, but no spark during TFI?
    • W
      Willie AlvarezAug 16, 2025
      Several issues could be the cause: * A shorted electrode. * The spark gap might not be correct. If so, set it to .094-.156 inch. * The high voltage cable might be faulty or have a poor connection. * A control failure.
  • K
    Kelly FoleyAug 20, 2025
    Why Alliance Laundry Systems Dryer has thermostat on, but no spark or valve?
    • C
      Christopher FlowersAug 20, 2025
      If the thermostat is on, but there's no spark or valve activity, check the red LED for steady on or flashing codes. This could be due to the cable connecting to the control and electrode, or voltage present at the gas valve or a bad control.
  • W
    walkersharonAug 26, 2025
    What to do if Alliance Laundry Systems Dryer has spark on, but no flame?
    • T
      Tanya ChapmanAug 26, 2025
      If there's a spark but no flame, consider these possibilities: * Check if the gas is turned on. * Ensure there's 24 VAC at the gas valve. * There could be a bad control. To check this, measure the voltage between the gas valve terminal MV and GND on the control.
  • C
    chaveztinaAug 30, 2025
    What to do if Alliance Laundry Systems Dryer has flame okay during TFI, but no flame sense after TFI?
    • S
      Sharon DavisAug 30, 2025
      If the flame is okay during TFI (Trial for Ignition) but there's no flame sense afterward, consider the following: * Check the electrode position and cleanliness. * Inspect the high voltage wire. * Ensure there's a good ground at the burner. * Check for a poor flame and verify the flame current.
  • N
    nicholaswarnerSep 4, 2025
    What to do if Alliance Laundry Systems Dryer reset failure?
    • L
      Laura AguirreSep 4, 2025
      If you're experiencing a reset failure, here are a couple of things to try: * If the reset switch was pressed too long, try to reset again. * If the reset switch is shorted, replace it.

Alliance Laundry Systems CA170L Specifications

General IconGeneral
BrandAlliance Laundry Systems
ModelCA170L
CategoryDryer
TypeCommercial
Phase1 or 3
Heating SourceElectric
Voltage208-240 V