WARNING
To prevent the risk of fire, remove laundry imme-
diately in case of power failure.
W779
Diagnostic Microprocessor Control
General Operation
The Diagnostic Microprocessor Control (DMP) is designed to
manage the drying and cooling cycles of the tumble dryer. The
controller is also programmed from the factory with five different
default programs as described below. The operator has the flexi-
bility to select the time for the drying and the cool down cycles
and the drying temperature. The operator may also select either
reversing or nonreversing basket action only if the tumble dryer
is equipped for reversing. The operator may also reprogram the
default programs. See Programming.
Default
Pro-
grams
Dry
Tim
e
(Mi
n.)
Cool
Time
(Min.)
Temp.
Set
Point
Re-
ver
s-
ing
1 – Towels 40 5 185º/195ºF
[85º/91ºC]
No
2 – Sheets 30 5 165ºF [74ºC] Yes
3 – Misc-1 30 5 150ºF [66ºC] No
4 – Misc-2 25 5 135ºF [57ºC] Yes
5 – Extra
Dry
5 2 150ºF [66ºC] No
NOTE: If an altered program is determined to be cor-
rupted, the default program settings will be used.
Features
• Drying time: 0-60 minutes
• Cooling time: 2-60 minutes
• LED display of cycle time, set temperature, and actual tem-
perature
• Thermistor controlled temperature
• Safety tumble cycle
• Buzzer for end of cycle, audible alarm
• Reversing/Nonreversing selection
• Five user programmable programs
• RPM display – when equipped with rotational sensor only
• Monitors the lint door switch operation
• Monitors the thermistor for operation
The minimum drying time is 0 minutes, and the minimum cool-
ing time is 2 minutes. The maximum drying or cooling time is 60
minutes. The drying temperature may be set from 100ºF [38ºC] to
185º/195ºF [85º/91ºC]. The drying time, cooling time, or temper-
ature may be modified during an operating cycle.
If it is necessary to reset the drying and cooling times for the cur-
rent cycle, press STOP once to stop the tumble dryer. Press
STOP again to cancel the cycle.
If it is necessary to change programs during a current cycle, press
STOP once to stop the tumble dryer and press STOP again to
cancel the current cycle.
DMP OPL Models
RD Control Suffix
Operating Instructions
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
71 Part No. 70458101ENR10