Properties of CE Gases
Gas
Type
Gas
Fami-
ly Group
Gas
De-
scrip-
tion
Gas
Desig-
nation
Wi Hi Ws Hs d
Wobb
e In-
dex
(net)
Heat-
ing
Value
(net)
Wobb
e In-
dex
(gross
)
Heat-
ing
Value
(gross
)
Densi-
ty
Btu/ft
3
[MJ/m
3
]
Btu/ft
3
[MJ/m
3
]
Btu/ft
3
[MJ/m
3
]
Btu/ft
3
[MJ/m
3
]
Natural
Gas
Second I
2H,E
Not Ap-
plicable
G20 1226
[45.67]
913
[34.02]
1362
[50.72]
1014
[37.78]
0.555
I
2E+
2H
I
2L
Not Ap-
plicable
G25 1004
[37.38]
785
[29.25]
1115
[41.52]
872
[32.49]
0.612
I
2E+
2L
LP Third I
3B/P
Not Ap-
plicable
G30 2164
[80.58]
3117
[116.09]
2345
[87.33]
3378
[125.81]
2.075
I
3+
Pure Bu-
tane
I
3+
Pure Pro-
pane
G31 1898
[70.69]
2363 [88] 2063
[76.83]
2568
[95.65]
1.55
I
3P
LPG with
Propane
Table 2
Changing Gas Configuration
1. Determine the necessary conversion operations to convert
from the factory-supplied configuration to the desired config-
uration.
2. Perform the conversions required so the machine is properly
configured for the desired country and gas. Refer to the fol-
lowing sections:
How to Convert Gas Valve from Regulated to Unregulat-
ed
How to Change Burner Orifice Size
How to Adjust Gas Valve Governor/Regulator
WARNING
When converting the tumble dryer to a different
gas or pressure, first verify that the supply inlet
pressure is equipped with a pressure regulator
(located ahead of the tumble dryer) that will main-
tain the gas supply at the inlet pressure specified.
W430R1
Installation
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT