Models
Prepurge Time
(seconds)
Trial for Ignition
(seconds)
Reset Lockout
Condition By:
Models starting
3/11/13 through
12/31/13
CE 1 10
(attempts to ignite 3
times)
For models with EO,
RE, RU or UO control
suffixes: Press start on
control keypad.
For models with all
other control suffixes:
Press and hold reset
button on junction box
until light goes out.
Models Starting 3/11/13 Non-CE and non-Aus-
tralian
1 10
(attempts to ignite 3
times)
Open loading door
Models starting 3/11/13
through 7/31/13
Australia 18 10 025, 030, 035, 055:
Press reset button on
rear of machine
T30, T45: Press lighted
reset button in rear
contactor box
Models starting 8/1/13 Australia 23 23 For models with EO,
RE, RU or UO control
suffixes: Press start on
control keypad.
For models with all
other control suffixes:
Press and hold ignition
control reset button.
Models Starting 1/1/14 CE
If the tumble dryer does not meet ANY of the listed requirements, remove tumble dryer from use. Refer to Removing Tumble Dryer
from Service section.
Required for CE Models Only
Once machine is installed, please be sure to complete the follow-
ing items:
Review and verify machine operation with customer.
Leave all literature and a signed Declaration of Conformity
with customer.
Review machine warranty information with customer.
Apply warning sticker on front panel of machine, in language
appropriate to country of sale (included in literature packet).
Installing CE Gas Drying Tumble Dryer
General Information
This information is to be used when installing gas tumble dryers
in countries and/or on gases different than the machine’s factory
configuration. Tumble Dryers are supplied from the factory for
operation on Natural Gas 1000 Btu/cu. ft. [8914 kcal/m
3
], or L.P.
Gas 2500 Btu/cu. ft. [22,250 kcal/m
3
], with natural gas group
H/E, designation G20 and L.P. gas group B/ P, designation G30.
To install machines in any other country, or on any other gas, re-
quires some level of modification.
Machines are built in two different configurations:
Natural Gas – regulated/governor
Liquefied Petroleum (L.P.) Gas – not regulated/no governor
For converting from Natural Gas to L.P. Gas, order 44240401P
L.P. Valve Conversion kit and orifice. Refer to CE Orifices.
Serial plates supplied from the factory are configured for
GB/IE/PT/ES/IT/GR/LU/CH/BE. These instructions pertain to
the situations when the country of use or gas supply is different
than that on the serial plate. If applicable, peel off the appropriate
Installation
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
30 Part No. 70458101ENR10