Alliance Laundry Systems CHD25G2-CA025L - User Manual

Alliance Laundry Systems CHD25G2-CA025L
136 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Installation/Operation/Maintenance
Tumble Dryers
25 Pound (11.3 Kilogram) Capacity
30 Pound (13.6 Kilogram) Capacity
35 Pound (16 Kilogram) Capacity
Stacked 30 Pound (13.6 Kilogram) Capacity
Stacked 45 Pound (20.4 Kilogram) Capacity
55 Pound (25 Kilogram) Capacity
Starting Serial No. 0602004144
Refer to Page 6 for Model Identification
Original Instructions
Keep These Instructions for Future Reference.
(If this machine changes ownership, this manual must accompany machine.)
www.alliancelaundry.com
Part No. 70458301ENR7
January 2014

Table of Contents

Questions and Answers

  • E
    eric78Aug 7, 2025
    What to do if Alliance Laundry Systems CHD25G2-CA025L Dryer has spark but no flame?
    • S
      Sean BrownAug 7, 2025
      If your Alliance Laundry Systems Dryer has a spark but no flame, first ensure the gas is on. Also, check for 24 VAC at the gas valve. If the issue persists, there might be a problem with the control; in this case check the voltage between the gas valve terminal MV and GND on the control.
  • J
    Julie FieldsAug 11, 2025
    Why Alliance Laundry Systems CHD25G2-CA025L valve is on but there is no spark during TFI?
    • A
      Anita ClaytonAug 12, 2025
      If the valve is on but there's no spark during TFI in your Alliance Laundry Systems Dryer, it could be due to a shorted electrode. Another possible cause is an incorrect spark gap; ensure it's set to .094-.156 inch. Also, inspect the high voltage cable for faults or poor connections. Finally, control failure can cause this issue.
  • B
    Brian GriffinAug 16, 2025
    What to do if Alliance Laundry Systems CHD25G2-CA025L Dryer flame is okay during TFI, but no flame sense after TFI?
    • M
      Mark BarnesAug 16, 2025
      If the flame is okay during TFI but there's no flame sense after TFI in your Alliance Laundry Systems Dryer, check the electrode position and cleanliness. Also, inspect the high voltage wire. Poor grounding at the burner or a poor flame (check flame current) can also cause this issue.
  • L
    laurabrownAug 20, 2025
    How to fix reset failure on Alliance Laundry Systems CHD25G2-CA025L Dryer?
    • D
      Donald WagnerAug 20, 2025
      If you're experiencing a reset failure on your Alliance Laundry Systems Dryer, it might be because the reset switch was pressed too long; try resetting again. Another possibility is that the reset switch is shorted, in which case you should replace the switch.
  • R
    Raymond KingAug 25, 2025
    What to do if Alliance Laundry Systems Dryer thermostat is on, but there is no spark or valve?
    • T
      Teresa YorkAug 25, 2025
      If the thermostat is on but there's no spark or valve activity in your Alliance Laundry Systems Dryer, first ensure the cable connects to the control and electrode, and that voltage is present at the gas valve. If the issue persists, the control might be bad; check the red LED for a steady on or flashing codes.
  • D
    duaneclayAug 28, 2025
    How to reset Alliance Laundry Systems CHD25G2-CA025L Dryer control in lockout mode?
    • J
      Jeffrey CraigAug 28, 2025
      If the control in your Alliance Laundry Systems Dryer is in lockout mode, a manual reset is needed. Reset it by pushing the red lockout button or use the front end control.
  • T
    Troy HartmanSep 2, 2025
    What to do if the Alliance Laundry Systems CHD25G2-CA025L control is in lockout mode?
    • K
      Kristie MeadowsSep 2, 2025
      If the control panel on your Alliance Laundry Systems Dryer is in lockout mode, you will need to manually reset it. You can do this by pushing the red lockout button or using the front end control.

Alliance Laundry Systems CHD25G2-CA025L Specifications

General IconGeneral
BrandAlliance Laundry Systems
ModelCHD25G2-CA025L
CategoryDryer
TypeCommercial
Capacity25 lb
Heat SourceGas
Fuel TypeNatural Gas
Width27 inches
Height43 inches
Voltage120V
Electrical Requirements120V, 60Hz, 15A
Exhaust Size4 inches
Gas Inlet Size3/8 in
Gas RequirementsNatural Gas