Electrical Requirements
82
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7
Conversion Instructions
If serial plate voltage is: Tumble Dryer can be converted to the following voltages:
120 Volt/60 Hertz/1 Phase
2W&G
(All models except T45)
208-240 Volt/60 Hertz/1 Phase Models:
3W&G
1. Prior to connecting service, locate the red or black with
red stripe wire which runs between terminal block and the
fan motor relay or contactor. Refer to figure below.
2. Disconnect the red or black with red stripe wire from L1
of the terminal block and connect to L2 of the terminal
block.
3. Sign and date conversion sticker located on back of
tumble dryer.
4. Follow the instructions covered in Connecting Electrical
Service section.
1
120 V~ Location (as received)
2
208 or 240 V~ Location (as converted)
3
To Fan Motor Relay or Contactor
4
RED or BLK With Red Stripe
NOTE: Motors operate on 120 Volt power regardless
of input voltage configuration.
240 Volt/60 Hertz/3 Phase
3W&G
200-208 Volt/60 Hertz/3 Phase Models:
3W&G
1. Prior to connecting electric service, locate transformer
configuration jumper in junction box area.
2. Remove the 240 Volt jumper and replace it with the 208
Volt jumper located in the literature packet in cylinder.
3. Sign and date conversion sticker located on back of
tumble dryer.
4. Follow the instructions covered in Connecting Electrical
Service section.