Operating Instructions
Part No. 70458301ENR7
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 123
7. Press the START button one last time to store the settings
and exit the program mode.
8. “PAy” will be displayed.
9. If it is determined that the data did not program correctly,
the error message “E2F” will flash for 4 seconds, and then
the default coin parameters will be used.
The tumble dryer run time per coin is programmable for 1 to 20
minutes with the default preset to 10 minutes.
The cooling run time is programmable from 2 to 5 minutes with
the default preset to 2 minutes.
The three temperatures setpoints are programmable for 100ºF
(38ºC) to 185º/195ºF (85º/90ºC) with the following default
settings:
- HIGH equal to 185ºF (85ºC)
- MEDIUM equal to 150ºF (66ºC)
- LOW equal to 135ºF (57ºC)
Stop
When in the Coin mode, the tumble dryer will stop if the tumble
dryer door is opened while the tumble dryer is running. If the
CLEAR button, located behind the board, is pressed, the tumble
dryer will stop, the tumble dryer time will be zeroed and the
display will show “PAy”.
Coin Count
The unit will count the number of coins deposited.
Setting DIP switch #7 to the ON position will display the coin
count since it was the last reset.
To reset the count, press the CLEAR button and “00” will be
displayed.
If the coin count is greater than “999”, the display will flash
“999”.
Setting DIP switch #7 to the OFF position will return the display
to “PAy”.
Ignition Control Operation and
Troubleshooting for Models Starting
3/11/13
WARNING
70458601 and 70458701 controls cannot be serviced
by the user. If any control failures are detected,
the controls must be replaced by qualified service
personnel. Risk of explosion or fire can result if
the control module has been opened or with any
attempts to repair it and the warranty is void.
W818
Before troubleshooting the system, check the following items:
- Verify all mechanical and electrical connections are secure and
tight.
- Verify all system wiring is correct.
- Verify there is a proper system ground. The igniter, flame
sensor and igniter module must share a common ground with the
burner. Nuisance shutdowns are often caused by a poor or erratic
ground.
- Verify that the system is powered and that the control is calling
for heat.
- If the control proceeds to an error code on the red diagnostic
LED, troubleshoot per the Fault conditions table below:
Fault Conditions
LED Indication Fault Mode
Off Normal Operation
1 Flash At Power Up
2 Flashes Flame Without Call For
Heat
3 Flashes Ignition Lockout
4 Flashes (70458701 only) Manual Reset Error