EasyManua.ls Logo

Alliance Laundry Systems CHD25G2-CA025L - Diagnostic Microprocessor Control

Alliance Laundry Systems CHD25G2-CA025L
136 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operating Instructions
118
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7
Figure 53
Temperature
Drying
Time
Cool
Down
Time
Left
Button
104°F (40°C) 30 min. 2
min.
Middle
Button
140°F (60°C) 30 min. 2
min.
Temperature
Drying
Time
Cool
Down
Time
Right
Button
176°F (80°C) 35 min. 2
min.
Table 32
IMPORTANT: To stop the tumble dryer at any
time during the cycle, OPEN DOOR. To restart
the tumble dryer, CLOSE door and press START
button.
3. When the cycle is complete, open door and remove the
laundry.
WARNING
To prevent the risk of fire, remove laundry
immediately in case of power failure.
W779
Diagnostic Microprocessor Control
General Operation
The Diagnostic Microprocessor Control (DMP) is designed
to manage the drying and cooling cycles of the tumble dryer.
The controller is also programmed from the factory with five
different default programs as described below. The operator
has the flexibility to select the time for the drying and the cool
down cycles and the drying temperature. The operator may also
select either reversing or nonreversing basket action only if the
tumble dryer is equipped for reversing. The operator may also
reprogram the default programs. See Programming.
Programs
Dry
Time
(Min.)
Cool
Time
(Min.)
Temp.
Set Point Reversing
1 – Towels 40 5 185º/195ºF
(85º/91ºC)
No
2 – Sheets 30 5 165ºF
(74ºC)
Yes
3 – Misc-1 30 5 150ºF
(66ºC)
No
Programs
Dry
Time
(Min.)
Cool
Time
(Min.)
Temp.
Set Point Reversing
4 – Misc-2 25 5 135ºF
(57ºC)
Yes
5 – Extra
Dry
5 2 150ºF
(66ºC)
No
Table 33 Default Programs
NOTE: If an altered program is determined to be
corrupted, the default program settings will be used.
Features
Drying time: 0-60 minutes
Cooling time: 2-60 minutes
LED display of cycle time, set temperature, and actual
temperature
Thermistor controlled temperature
Safety tumble cycle
Buzzer for end of cycle, audible alarm
Reversing/Nonreversing selection
Five user programmable programs

Table of Contents

Related product manuals