Installation
Part No. 70458301ENR7
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 47
• Apply warning sticker on front panel of machine, in language
appropriate to country of sale (included in literature packet).
Installing CE Gas Drying Tumble Dryer
General Information
This information is to be used when installing gas tumble dryers
in countries and/or on gases different than the machine’s factory
configuration. Tumble Dryers are supplied from the factory for
operation on Natural Gas 1000 Btu/cu. ft. (8914 kcal/m
3
), or
L.P. Gas 2500 Btu/cu. ft. (22,250 kcal/m
3
), with natural gas
group H/E, designation G20 and L.P. gas group B/P, designation
G30. To install machines in any other country, or on any other
gas, requires some level of modification.
Machines are built in two different configurations:
• Natural Gas – regulated/governor
• Liquefied Petroleum (L.P.) Gas – not regulated/no governor
For converting models from Natural Gas to L.P. Gas:
025 series M4699P3
030 series M4703P3
035 series M4711P3
055 series M4924P3
T30/T45 series M4734P3
Serial plates supplied from the factory are configured for GB/
IE/PT/ES/IT/GR/LU/CH/BE. These instructions pertain to the
situations when the country of use or gas supply is different than
that on the serial plate. If applicable, peel off the appropriate
country sticker (included with machine) and apply it to the serial
plate over the existing country information.
These instructions are only valid if the following country code
is on the appliance: GB/IE/PT/ES/IT/GR/LU/CH/BE. If this
code is not present on the appliance, it is necessary to refer
to the technical instructions which will provide the necessary
information concerning the modification of the appliance to the
condition of use for the country.
Before installation, check that the local distribution conditions,
nature of gas and pressure, and the adjustment of the appliance
are compatible.
Table 1 describes the different gases that are available in
different CE countries, and how the machines need to be
configured to operate with those gases. In the CE, there are
Natural Gas configurations that do not allow for machine
regulation and L.P. Gas configurations that must be regulated.
For L.P. Gas, third family B/P at 50 mbar (5 kPa), order
Regulated Natural Gas machines and convert according to Table
1.
CE Orifices
Gas
Type
Gas
Family
Gas
Group
Gas
Designation
Supply
Pressure
in. wc
(mbar, kPa)
Manifold
Pressure
in. wc
(mbar, kPa)
Capacity
Model
Orifice
Diameter
in. (mm)
Orifice
Part No. Quantity
25 0.1540
(3.9)
M401020 1
30 0.1570
(4.0)
M402996 1
T30 0.1570
(4.0)
M402996 2
Natural
Gas
Second I
2H(E)
G20 8/10
(20/25, 2.0/2.5)
3.25
(8, 0.8)
35 0.1820
(4.6)
M411371 1