Before You Call for Service
Part No. 70458301ENR7
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 134
Before You Call for Service
Won’t Start Won’t Heat Clothes Not Dry Possible Reason – Corrective Actions
Insert correct coin(s) or valid card if applicable.
Close the loading door tightly.
Close lint panel tightly.
Press the PUSH-TO-START or START pad/button.
Be sure power cord is plugged all the way into the
electrical outlet.
Drying timer is in OFF position.
Check the main fuse and circuit breaker.
Check fuses located in the machine.
Insufficient airflow.
Gas shut-off valve in OFF position.
Are controls properly set?
Broken drive belt. Call the service person.
Tumble dryer is in Cool Down Mode.
Lint screen clogged. Clean lint screen.
Exhaust duct to outside is blocked. Clean out.