Installation
Part No. 70458301ENR7
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 51
Wi Hi Ws Hs d
Wobbe
Index
(net)
Heating
Value
(net)
Wobbe
Index
(gross)
Heating
Value
(gross)
Gas
Type
Gas
Family Group
Gas
Description
Gas
Designation
Btu/ft
3
(MJ/m
3
)
Btu/ft
3
(MJ/m
3
)
Btu/ft
3
(MJ/m
3
)
Btu/ft
3
(MJ/m
3
)
Density
I
2E+
2L
I
3B/P
Not
Applicable
I
3+
Pure
Butane
G30 2164
(80.58)
3117
(116.09)
2345
(87.33)
3378
(125.81)
2.075
I
3+
Pure
Propane
LP Third
I
3P
LPG with
Propane
G31 1898
(70.69)
2363 (88) 2063
(76.83)
2568
(95.65)
1.55
Table 2
Changing Gas Configuration
1. Determine the necessary conversion operations to convert
from the factory-supplied configuration to the desired
configuration.
2. Perform the conversions required so the machine is properly
configured for the desired country and gas. Refer to the
following sections:
• How to Convert Gas Valve from Regulated to
Unregulated
• How to Change Burner Orifice Size
• How to Adjust Gas Valve Governor/Regulator
WARNING
When converting the tumble dryer to a different
gas or pressure, first verify that the supply inlet
pressure is equipped with a pressure regulator
(located ahead of the tumble dryer) that will
maintain the gas supply at the inlet pressure
specified.
W430R1