Electrical Requirements
76
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7
• A dedicated ground conduit (wire) must be connected
between the electrical service box ground bar and tumble
dryer ground screw.
WARNING
To reduce the risk of electrical shock, de-energize
the electrical circuit being connected to the tumble
dryer before making any electrical connections.
All electrical connections should be made by a
qualified electrician. Never attempt to connect a live
circuit.
W409R1
CAUTION
Label all wires prior to disconnection when
servicing controls. Wiring errors can cause
improper and dangerous operation. Verify proper
operation after servicing.
W071
For CE Models Only
All OPL (non-vend) models are factory-equipped with an
emergency stop button on the front panel. If the emergency
stop function is desired on coin-operated models, an external
emergency stop button may be installed.
NOTE: Activation of the emergency stop switch stops
all machine control circuit functions, but DOES NOT
remove all electrical power from machine.
Service/Ground Location
Models Through 7/9/12 Heat Source Ground and Terminal Block Locations
Non-CE
025
030
035
055
Gas or Steam Control Tray
1. Ground Screw
2. Terminal Block