Electrical Requirements
80
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7
Model Heat Source
Ground and Terminal
Block Locations
CE
T30
Electric
1. Ground Lug
2. Power Disconnect (Models Through
7/31/11)
3. Power Distribution Block
To Connect Electrical Service To The
Tumble Dryer
The following steps outline the procedure for connecting
electrical service to the tumble dryer.
3 Phase Models – Each tumble dryer must be connected to its
own individual branch circuit breaker, not fuses, to avoid the
possibility of “single phasing” and causing premature failure
of the motor(s).
Electrical service must be connected using the appropriate
permanent rigid metal conduit system.
Service conductors must be copper only.
For an existing service, determine your service voltage and
conductor amperage. Carefully review the tumble dryer serial
plate ratings and Electrical Requirements section of this manual.
If service is inadequate it must be upgraded by a qualified
electrical contractor. Never connect an improper or inadequate
service to any machine.
Configuring Your Tumble Dryer for
Other Service Voltages
Several gas and steam tumble dryer models have been designed
to be field convertible to other service voltages. Refer to Table
11 for these models:
Models
If your Serial
Plate voltage is:
Your tumble
dryer can be
converted to
the following
voltages:
025, 030, 035,
055, T30
120 Volt/60
Hertz/1 Phase
208-240 Volt/60
Hertz/1 Phase
025, 030, 035,
055, T30
200-220 Volt/60
Hertz/1 Phase
100 Volt/60
Hertz/1 Phase
025, 030, 035,
055, T30
200 Volt/50
Hertz/1 Phase
100 Volt/50
Hertz/l Phase
025, 030, 035,
055, T30, T45
240 Volt/60
Hertz/3 Phase
200-208 Volt/60
Hertz/3 Phase
025, 030, 035,
055, T30
380 Volt/50
Hertz/3 Phase
400-415 Volt/50
Hertz/3 Phase
Table 11
NOTE: Electric models are not field convertible and
must be connected to service specified on serial plate.