Operating Instructions
110
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7
Display Definition Corrective Action
OP Open thermistor error • Check thermistor. Replace if inoperative.
• Check wiring diagram between control and thermistor.
Refer to wiring diagram for proper wiring.
• Check control. Replace if inoperative.
SH Shorted thermistor error • Check thermistor. Replace if inoperative.
• Check wiring between control and thermistor. Refer to
wiring diagram for proper wiring.
• Check control. Replace if inoperative.
AF - 1 Airflow switch closed when cycle started • Check airflow switch. Replace if inoperative.
AF - 2 Airflow switch failed to close after cycle
started
• Check airflow switch. Replace if inoperative.
AF (Flashing) Bouncing Airflow Switch • Check airflow switch to ensure that it is properly
aligned and securely mounted in the mounting bracket.
• Make sure airflow switch can open and close freely.
• Check installation and make sure there is adequate
airflow.
• Make sure exhaust is not blocked.
• Clean the lint screen.
• Replace airflow switch if inoperative.
AF (Solid) Airflow Switch Closed when Resuming
Cycle
• Allow up to 20 seconds for this condition to clear.
• Check if airflow switch opens at end of cycle.
• Replace airflow switch if inoperative.
Table 30 Error Codes
Electronic OPL Micro Control
OM Control Suffix
1. To use an Automatic Cycle, press an ON/SELECT pad.
Select HIGH, MEDIUM, MED LOW, LOW or NO HEAT
for items that should not be dried with heat. A light to the
left of the selected pad lights up.
HIGH temperature* 185°F (85°C)
HIGH temperature** 190°F (88°C)
MED temperature* 160°F ( 71°C)
MED temperature** 165°F ( 74°C)
MED LOW temperature* 145°F (63°C)
MED LOW
temperature**
155°F (68°C)
LOW temperature
(025-055)
120°F (49°C)
* = (025, 030)
** = (035, 055)
To use a Time Dry or Custom Cycle, refer to the Programming
Manual.