Display Definition Corrective Action
OP Open thermistor error Check thermistor. Replace if inoperative.
Check wiring diagram between control and thermistor.
Refer to wiring diagram for proper wiring.
Check control. Replace if inoperative.
SH Shorted thermistor error Check thermistor. Replace if inoperative.
Check wiring between control and thermistor. Refer to
wiring diagram for proper wiring.
Check control. Replace if inoperative.
AF - 1 Airflow switch closed when cycle started Check airflow switch. Replace if inoperative.
AF - 2 Airflow switch failed to close after cycle
started
Check airflow switch. Replace if inoperative.
AF (Flashing) Bouncing Airflow Switch Check airflow switch to ensure that it is properly
aligned and securely mounted in the mounting bracket.
Make sure airflow switch can open and close freely.
Check installation and make sure there is adequate
airflow.
Make sure exhaust is not blocked.
Clean the lint screen.
Replace airflow switch if inoperative.
AF (Solid) Airflow Switch Closed when Resuming
Cycle
Allow up to 20 seconds for this condition to clear.
Check if airflow switch opens at end of cycle.
Replace airflow switch if inoperative.
Table 30 Error Codes
Electronic OPL Micro Control
OM Control Suffix
1. To use an Automatic Cycle, press an ON/SELECT pad.
Select HIGH, MEDIUM, MED LOW, LOW or NO HEAT
for items that should not be dried with heat. A light to the
left of the selected pad lights up.
HIGH temperature* 185°F (85°C)
HIGH temperature** 190°F (88°C)
MED temperature* 160°F ( 71°C)
MED temperature** 165°F ( 74°C)
MED LOW temperature* 145°F (63°C)
MED LOW
temperature**
155°F (68°C)
LOW temperature
(025-055)
120°F (49°C)
* = (025, 030)
** = (035, 055)
To use a Time Dry or Custom Cycle, refer to the Programming
Manual.