Gas Requirements
66
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7
For proper operation at altitudes above 2,000 feet (610 m),
the gas burner orifice size must be reduced to ensure complete
combustion. Refer toTable 6 Classic Line Modelsor Table 7 Eco
Line Models.
For CE models, consult local gas supplier.
Altitude Burner Orifice New Rate
Model Gas feet (meters) No.
inches
( mm) Quantity Part No.
Btu/hr.*
(Mj/hr.)
2,001-4,000
(610-1,220)
26 0.1470 (3.7) M401000 58,880
(62.12)
4,001-6,000
( 1,221-1,830)
27 0.1440 (3.7) M400998 53,760
(56.72)
6,001-8,000
( 1,831-2,440)
28 0.1405 (3.6) M401014 48,640
(51.32)
Natural
Gas
8,001-10,000
( 2,441-3,050)
29 0.1360 (3.4) M400997 43,520
(45.91)
2,001-6,000
(610-1,830)
43 0.0890 (2.3) M406184 58,880
(62.12)
6,001-8,000
( 1,831-2,440)
44 0.0860 (2.2) M401011 48,640
(51.32)
025 Series
L.P. Gas
8,001-10,000
( 2,441-3,050)
46 0.0810 (2.1)
1
M401003 43,520
(45.91)
2,001-4,000
( 610-1,220)
22 0.1570 (4.0) M402996 67,160
(70.85)
4,001-6,000
(1,221-1,830)
24 0.1520 (3.9) M402980 61,320
(64.69)
6,001-8,000
( 1,831-2,440)
26 0.1470 (3.7) M401000 55,480
(58.53)
Natural
Gas
8,001-10,000
( 2,441-3,050)
28 0.1405 (3.6) M401014 49,640
(52.37)
030 Series
L.P. Gas 2,001-6,000
( 610-1,830)
42 0.0935 (2.4)
1
M403017 67,160
(70.85)