60 39201
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Troubleshooting (EDC Models)
32. Cannot Perform Infrared Communication
Attempt to communicate
with the electronic control
from the Micro-wand.
Check the following:
– Low battery on Micro-wand.
– Is the (IR) on the control
covered or blocked?
– If needed, replace electronic
control board.
– Is the (IR) cap properly
attached to the Micro-wand?
Check the following:
– (IR) disabled by manual prog.
– Is the (IR) on the control
covered or blocked?
– If needed, change electronic
control board.
Aim Micro-wand
closer and try
again.
Communication
sequence checks
out.
YES
YES
NO NO
Is
there any
acknowledgement
of any kind from
the electronic
control?
Is
there any
control
response?
Does
the electronic
control display
"E:OF" or
"– C–" ?
"– C–"
"E:OF"
W367S