38. Overflow Analysis
Washer has
overflowed.
Check for a
locked open
mixing valve.
Open
control
panel
NOTE: The diaphragms on the mixing valve
may lock open. The way to test this
problem is to unplug the washer
and see whether the mixing valve
allows water to come in. If this
happens, replace the mixing valve.
NO
After checking for
correct wiring, replace
pressure switch or
pressure hose.
YES
(1)
Check
voltage at
pressure switch
BLU/WHT "2" to "H3-3"
when wash tub
is full, is there
voltage?
W376S
(#) Numbers next to voltage checks
correspond to the locations marked
on the wiring schematic.