EasyManua.ls Logo

Alliance Laundry Systems WF150 - Electrical Specifications WF185, IWF185, IWF040, CWF185, CWF040

Alliance Laundry Systems WF150
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4
37
WARNING
The washer-extractor should be connected to an individual branch
circuit not shared with lighting or other equipment.
4
Electrical Specications WF185, IWF185, IWF040, CWF185, CWF040
185 liters / 40 pounds
Boiler Fed/Steam Heat Electric Heat
Code
Voltage
Cycle
Phase
Wire
Full Load Amps
Recommended Circuit
Breaker (US-market)
AWG/mm2
kW Standard
Heating Elements
Full Load Amps
Recommended
Circuit Breaker (US-
market)
AWG/mm2
US NON-US US NON-US
N 440-480 50/60 3 3+PE 4 10 10 14/2.5
6x3 kW
30 40 40 8/10.0
P 380-415 50/60 3 3+N+PE 12 15 16 14/2.5 38 50 50 8/10.0
Q 200-240 50/60 3 3+PE 12 15 16 14/2.5 57 70 70 4/25.0
X 200-240 50/60 1/3 2/3+PE 12 15 16 14/2.5 N/A N/A N/A N/A
Alternative Electric Heat Options
N 440-480 50/60 3 3+PE
3x3 kW +
3x2 kW
26 30 30 10/6.0
P 380-415 50/60 3 3+N+PE 34 40 40 8/10.0
Q 200-240 50/60 3 3+PE 50 60 60 6/16.0
X 200-240 50/60 1/3 2/3+PE 50 60 60 6/16.0
N 440-480 50/60 3 3+PE
3x3 kW +
3x4 kW
34 40 40 8/10.0
P 380-415 50/60 3 3+N+PE 53 60 60 6/16.0
Q 200-240 50/60 3 3+PE N/A N/A N/A N/A
X 200-240 50/60 1/3 2/3+PE N/A N/A N/A N/A
N 440-480 50/60 3 3+PE
6x2 kW
21 30 30 10/6.0
P 380-415 50/60 3 3+N+PE 30 40 40 8/10.0
Q 200-240 50/60 3 3+PE 42 50 50 8/10.0
X 200-240 50/60 1/3 2/3+PE N/A N/A N/A N/A
N 440-480 50/60 3 3+PE
6x4 kW
39 50 50 8/10.0
P 380-415 50/60 3 3+N+PE 47 60 60 6/16.0
Q 200-240 50/60 3 3+PE N/A N/A N/A N/A
X 200-240 50/60 1/3 2/3+PE N/A N/A N/A N/A
Table 4