FIGURE 44 - PLATEN CONNECTOR - REFERENCE ONLY
RTD PROBE RESISTANCE
HEATING ELEMENT RESISTANCE
FAULT CORRECTION
10.4. VULCANIZER OVERHEATING
10.4.1. Temperature set improperly. Ensure that Temperature Set Point is correct. (SEE SECTION 7.1.1.)
10.4.2. Faulty Contactor in SG1 control panel. Replace Contactor. (SEE SG1 PARTS LIST &SCHEMATIC DIAGRAM)
10.4.3. Faulty RTD Temperature Sensor in platen. Refer to the Maintenance Section in the Operator’s Manual
of the Almex Press.
10.4.4. Faulty Temperature Controller in SG1 Replace Omron Temperature Controller.
control panel.
10.5. UNIT FAILS TO CREATE SG1 NETWORK
FAULT CORRECTION
10.5.1. Improper network configuration. Ensure network is connected according to (SEE SECTION 8)
10.5.2. Faulty network connectors. Check network cables for continuity. Replace cables and terminators
if necessary.
10.5.3. Faulty communication on SG1 motherboard Contact Shaw Almex.
10. Troubleshooting CONTINUED
Shaw Almex Industries | 1.800.461.4351 | www.almex.com
16
Revised - April 2014 49900-038
NOTE: IF TROUBLESHOOTING STEPS HAVE BEEN PERFORMED AND THE PROBLEM PERSISTS,
PLEASE CALL SHAW ALMEX FOR FURTHER SERVICE. (SEE SECTION 12)