Maintenance and Troubleshooting
10.2.2. Battery Protection Description
Wait for automated
recovery.
In case the problem is not
recovery for a long time, call
for service.
Stop discharging and
charging until this code is
eliminated and wait for the
temperature to drop.
Low-
temperature
discharge
Stop discharging until this
code is eliminated and wait
for the temperature to rise.
Wait for automated
recovery.
In case the problem is not
recovery for a long time, call
for service.
Stop charging and call
service immediately.
Stop charging until this code
is eliminated and wait for
the temperature to rise.
In the case of work mode, if the protection code 9 appears, please press the power
button of the battery 5 times within 10 seconds, the BMS will be forced to turn on the
MOSFET of discharge so that the inverter can detect the battery open voltage and
charge the battery.