Installation site requirements
● Only install outdoors
Clearance dimensions were complied with
“Installation plans”
Noisespecicationsonpage15
Free air intake and blowing air are pos-
sible without any air short-circuit.
Thesurface/oorissuitableforinstallationofthedevice:
● Level and horizontal
● With load-bearing capacity for the device’s weight
5.5 Installation with a wall bracket
“Wall bracket installation instruction”
“Wall duct installation instruction”
“Installation plans/minimum clearances/
drill template”
The wall bracket is only suitable for solid, load-bearing
walls. In a timber-frame construction with facing, the
oorbracketshouldbeusedduetothepossibletrans-
fer of structurally borne sound to the interior.
5.6 Installationonaoorbracket
The device can be installed near a wall or as a free
eldinstallation. Ideally,theheatpump should bein-
stalled where it is protected from wind. If this is not
possible, we recommend installing it at right angles
to the prevailing direction of wind or air ducting in the
main wind direction.
Placethedeviceonaload-bearing,rmandhorizontal
foundation. The foundation must not be connected to
the building Make sure that the foundation is designed
for the weight of the heat pump.
“Floor bracket installation instruction”
“Wall duct installation instruction”
“Installation plans/minimum clearances/
view of foundation”
NOTE
When installing with a wall duct, make sure
the wall clearance is correct.