SENSOR DETAILS TABLE
°C (hi res)
°C (lo res)
°F (hi res)
°F (lo res)
0.0 to 999.9
0 to 1300
32.0 to 999.9
32 to 2372
OrangeMTP-N-MN
°C (hi res)
°C (lo res)
°F (hi res)
°F (lo res)
-199.9 to 800.0
-270 to 800
-199.9 to 999.9
-454 to 1470
PurpleMTP-E-ME
°C (hi res)
°C (lo res)
°F (hi res)
°F (lo res)
-199.9 to 400.0
-270 to 400
-199.9 to 750.0
-454 to 750
BlueMTP-T-MT
°C (hi res)
°C (lo res)
°F (hi res)
°F (lo res)
-199.9 to 999.9
-270 to 1370
-199.9 to 999.9
-454 to 2500
YellowMTP-K-MK
°C (hi res)
°C (lo res)
°F (hi res)
°F (lo res)
0.0 to 815.0
0 to 815
32.0 to 999.9
32 to 1500
BlackMTP-J-MJ
Only Thermocouples require different connectors:Thermocouples
User specified
2
Use the range
variables to scale
the temperature.
3
User specified from
-1999 to 9999 units
Scale the sensor
output to one of the
process inputs.
WhiteMTP-U-M
Process:
0 to 10 Volts
0 to 5 Volts
1 to 5 Volts
0 to 20mA
4 to 20mA
°C
°F
-50 to +150
-58.0 to +302.0
WhiteMTP-U-M
3 Wire RTD
°C
°F
°K
-50 to +150 (default)
-58.0 to +302.0
+223.2 to +423.2
WhiteMTP-U-M
AD590
°C
°F
°K
-50 to +150 (default)
-58.0 to +302.0
+223.2 to +423.2
WhiteMTP-U-MLMx35
°C
°F
°K
-50 to +150 (default)
-58.0 to +302.0
+223.2 to +423.2
WhiteMTP-U-MLM35
Kohms
1
Kohms
0 to 99.99 (default)
0 to 999.9
WhiteMTP-U-M
Thermistor
Front Panel UnitsTemperature RangesColorOmega Mating Part #Sensor Type
Note: The sensor mating connector is supplied according to the sensor specified at
the time of order.
ALPHA OMEGA INSTRUMENTS CORP. Instruction Manual
Series 800/850 Thermoelectric Cooler Controller Page 56
3
Example: 0 to 10V represents 0°C to 100°C. Set [rl`1] to 0.00 and [rh`1] to 100.0. Note: For °F simply convert
[rl`1] & [rh`1]. Using example above, set [rl`1] to 32.0 and [rh`1] to 212.0.
2
Please see example on next page.
1
Other units are available via EIA/RS-232/485 (optional) using the optional TECView software (see Appendix B under TECView).
Note: Thermistors will always display Kohms on the front panel, however, the TECView software will convert to/from °C or °F
using the Steinhart Hart equation.