15
Setting Up a 15A Model:
BydefaultthesespapoolswillNOTdrawmorethan15Aatanyonetime.Thisis
thedefaultfactorysetupwhichload-sheds(disables)theheaterwhenthepumps
(jets)areturnedon*.
A15ampcablewith3-pinplughasbeenpre-wiredtothespapool’ssystem
controllerandcanbefoundcoiledupinsidethecabinet.Tondoutwhichcabinet
toremovetoaccessthecable,seeyourspapool’scorrespondingtechinfo/wiring
page(usingthetableonthepreviouspage).
Setting Up a 25A or 32A Model
A15Aspapoolrequiresa15Aelectricalsocketprotectedbya
residualcurrentdevice(RCD)forthedefaultsetup.
A25Aor32Aspapoolrequiresadedicatedfeedfromyourcircuit
boardandappropriateResidualCurrentDevice&Isolationswitch.
Anelectricianisrequiredtosetupandconnecttheappropriatewiringand
accessories.Tolocatethesystemcontroller,seeyourspapool’scorresponding
techinfo/wiringpage(usingthetableonthepreviouspage).
Thecableshouldbefedthroughthecabinetwall.Acablegrommetissuppliedin
theiPackshouldyouwishtousethisandadrillwitha60mmhole-sawattachment
willprovidetherightsizeforthegrommet(seeaboveimage).Alternatively,a
tightertcanbeachievedwithoutthegrommetbyjustusingadrillbitthesame
sizeastheexdiameteranddrillingthroughthecabinetwall.
Informationtodisableloadshed(changing15Ato25A)canbe
downloadedfromoursupportpage:http://alpinespas.co.nz/support/
*NOTE: The default 15A setup is the most economical way to run the spa pool. If you wish
to avoid load-shed, a 25A supply would need to be hardwired to your switchboard. A guide
for your electrician to achieve this can be downloaded from our support page.
Thecablecanbeexitedthroughthecabinetwall(acable
grommetissuppliedintheiPack).Adrillwitha60mm
hole-sawattachmentwillprovidetherightsizeforthe
grommet.
Cable grommet after installation