3
2 Shipping Inspection
Always transport the unit upright; laying the unit on its side
or top during transit may cause equipment damage. The
installer should inspect the product upon receipt for shipping
damage and subsequent investigation is the responsibility
of the carrier. The installer must verify the model number,
correct prior to installation. The distributor or manufacturer
will not accept claims from dealers for transportation damage
or installation of incorrectly shipped units.
2.1 Parts
Also inspect the unit to verify all required components
are present and intact. Report any missing components
immediately to the manufacturer or to the distributor.
Use only factory authorized replacement parts (see
Section 5). Make sure to include the full product model
number and serial number when reporting and/or
obtaining service parts.
2.2 Handling
Use caution when transporting / carrying the unit. Do
not move unit using shipping straps. Do not carry unit
with hooks or sharp objects. The preferred method of
carrying the unit after arrival at the job site is to carry
via a two-wheel hand truck from the back or sides or via
hand by carrying at the cabinet corners.
3 Codes & Regulations
This product is designed and manufactured to comply with
applicable national codes. Installation in accordance with
such codes and / or prevailing local codes / regulations is
the responsibility of the installer. The manufacturer assumes
no responsibility for equipment installed in violation of any
codes or regulations.
The United States Environmental Protection Agency
follow these regulations may harm the environment and
. Should
EPA and / or refer to EPA’s website www.epa.gov.
4 Replacement Parts
When reporting shortages or damages, or ordering repair
parts, give the complete product model and serial numbers
as stamped on the product. Replacement parts for this
product are available through your contractor or local
distributor. For the location of your nearest distributor consult
the white business pages, the yellow page section of the
local telephone book or contact:
HOMEOWNER SUPPORT
DAIKIN COMFORT TECHNOLOGIES
MANUFACTURING, L.P.
19001 KERMIER ROAD
WALLER, TEXAS 77484
(855) 770-5678
5 Pre-Installation Considerations
5.1 Preparation
Keep this document with the unit. Carefully read all
instructions for the installation prior to installing product.
Make sure each step or procedure is understood and
any special considerations are taken into account
before starting installation. Assemble all tools, hardware
and supplies needed to complete the installation. Some
items may need to be purchased locally. Make sure
everything needed to install the product is on hand
before starting.
5.2 System Matches
The entire system (combination of indoor and outdoor
sections) must be manufacturer approved and Air-
Conditioning, Heating, and Refrigeration Institute (AHRI)
listed. NOTE: Installation of unmatched systems is not
permitted.
5.3 Interconnecting Tubing
Give special consideration to minimize the length of
refrigerant tubing when installing air handlers. Refer
to Remote Cooling / Heat Pump Service Manual
RS6200006, and TP-107 Long Line Set Application
R-410A for tubing guidelines. If possible, allow adequate
length of tubing such that the coil may be removed (for
inspection or cleaning services) from the cabinet without
disconnecting the tubing.
5.4 Clearances
The unit clearance from a combustible surface may be
0”. However, service clearance must take precedence. A
minimum of 24” in front of the unit for service clearance
is required. Additional clearance on one side or top will
be required for electrical wiring connections. Consult all
clearances. When installing this unit in an area that
may become wet (such as crawl spaces), elevate the
unit with a sturdy, non-porous material. In installations
that may lead to physical damage (i.e. a garage) it is
advised to install a protective barrier to prevent such
damage. Always install units such that a positive slope
5.5 Horizontal Applications
drain pan (as required by many building codes), must be
installed under the entire unit and its condensate drain
line must be routed to a location such that the user will
see the condensate discharge.