Layout and function
72
D9 BAH0041-4 08.18
5.14.1 Recalculation of the crank turns on the wheel due to slippage
on seed drills with electronically regulated seed rate adjustment
The electronically regulated seed rate adjust-
ment has an electric motor (Fig. 70/1), which
actuates the gearbox lever (Fig. 70/2).
The AMADRILL+ calculates the required gear
setting based on the data from the calibration
test and moves the gearbox lever to the required
gearbox position.
Fig. 70
Based on the "AMADRILL+" operating manual,
determine the calibration value [pulses/100m]
perform the calibration test for seed drills with electronically regulated seed rate adjustment.
The calibration values [pul./100 m] and crank turns listed in the table (Fig. 71) were determined during
a calibration run on a standardized field with the AmaDrill+ control terminal.
AMADRILL+
Calibration value [pul./100 m]
740
711
711