12
www.dunkermotoren.de Version 05.2017
5.4 Motor specication
BG65Sx25 MI
Nominal voltage 24 V
Nominal power 176 W
Nominal torque 41,6 Ncm
2)
Recommended
speed control range
100 min
-1
...
Nominal speed
Nominal speed 3065 rpm
Maximal permitted
continuous current
7,3 A
Maximum peak current
per motor phase
19 A (for 75 sec. @20°C)
Nominal voltage 40 V
Nominal power 187 W
Nominal torque 45,7 Ncm
2)
Recommended
speed control range
100 min
-1
...
Nominal speed
Nominal speed 3220 rpm
Maximal permitted
continuous current
4,6 A
Maximum peak current
per motor phase
12 A (for 77 sec. @20°C)
2)
The nominal torque depends on how the motor is
cooled. For this reason, the nominal torque is
measured according to VDE/EN.
Values for dierent operating voltages can be found in
corresponding specications. These are available on
request.
5.4 Motorspezikationen
BG65Sx25 MI
Nennspannung 24 V
Nennleistung 176 W
Nenndrehmoment 41,6 Ncm
2)
empfohlener
Drehzahlregelbereich
100 min
-1
...
Nenndrehzahl
Nenndrehzahl 3065 U/min
Maximal zulässiger
Dauerstrom
7,3 A
Max. Spitzenstrom in der
Motorphase
19 A (für 75 sec. @20°C)
Nennspannung 40 V
Nennleistung 187 W
Nenndrehmoment 45,7 Ncm
2)
empfohlener
Drehzahlregelbereich
100 min
-1
...
Nenndrehzahl
Nenndrehzahl 3220 U/min
Maximal zulässiger
Dauerstrom
4,6 A
Max. Spitzenstrom in der
Motorphase
12 A (für 77 sec. @20°C)
2)
Das Nenndrehmoment ist abhängig von der Wärme-
abführung des Motors. Deshalb sind die Nenndrehmo-
mente gemessen nach VDE/EN.
Werte für abweichende Betriebsspannungen sind den
entsprechenden Spezikationen zu entnehmen. Diese
sind auf Anfrage erhältlich.
Überschreiten der maximal zulässigen
Dauerströme!
Die Folge:
Kann zur Zerstörung des Antriebs
führen.
► Die maximal zulässigen Dauerströme
beachten!
VORSICHT
Exceeding of the maximum permitted
continuous current!
Consequence:
The drive may be
destroyed.
► Mind the maximum permitted
continuous current!
CAUTION