SPOT+
2 - 3 REST API User Guide
2.2 List Identity
The following functions are supported:
Implicit Messaging for Assembly (4), Identity (101, 102, 103, 198 and 199),
Attribute (3).
Explicit Messaging is not supported.
Identity info:
101: Output data from the SPOT+
typedef struct{
uint16_t targetTemp;
uint16_t emissivity1;
uint16_t emissivity2;
uint16_t ambientTemp;
uint16_t alarmStatus;
uint16_t watchdog;
uint16_t errors;
}sOutputData;
102: Input data to the SPOT+
typedef struct{
uint16_t emissivity1;
uint16_t emissivity2;
}sEthIpIoInData;
103: Cong Data
Not currently used
2.3 Example Data
The screenshot below shows an EtherNet/IP client congured to communicate
with Spot+. The Input and output parameters are shown in the relevant
windows.