21
EV3000
COMMISSIONING LOG BOOK
13 Illustrations
E V 3 0 0 0
ISOLATE AUTOMATIC
MANUAL
REMOTE E.C.P.
IN CONTROL
ALL
EVAC
ALL
ALERT
ALL
P.A.
CANCEL
LAMP
TEST
SYSTEM
TEST
ALARM SYSTEM
FAULT
VISUAL
LINE FAULT
EIAD
FAULT
AMPLIFIER/SPEAKER
FAULT
MICROPHONE
FAULT
MODULE
FAULT
SYSTEM
FAULT
COMMS
FAULT
ALARM SYSTEM
ISOLATED
TONE
FAULT
BATTERY
ISOLATED
BATTERY
FAULT
CHARGER
FAULT
SYSTEM ON
BATTERIES
POWER
ON
ALL CALL SYSTEM STATUS
ZONE STATUS
EMERGENCY OPERATING INSTRUCTIONS
EMERGENCY WARNING SYSTEM (E.W.S.)
1. TO SILENCE AUTOMATIC TONES
PLACE KEYSWITCH IN MANUAL POSITION.
2. INDIVIDUAL ZONE OPERATION
PUBLIC ADDRESS
3. ALL ZONE OPERATION
PRESS REQUIRED 'ALL CALL' SWITCH.
4. TO RESTORE E.W.S. TO NORMAL
PRESS BUZZER MUTE/ACK , MASTER RESET
EMERGENCY INTERCOMMUNICATION SYSTEM (E.I.S.)
1. TO CALL INDIVIDUAL WIP
2. TO ANSWER INCOMING CALL
3. TO TERMINATE CALL
4. TO 'ALL CALL' WIPS
5. TO TERMINATE ALL CALL
6. ZONE CLEARED
PRESS ZONE CLEARED SWITCH FOR ZONE CLEARED INDICATOR
ON OR OFF. (MASTER WIP HANDSET MUST BE LIFTED).
(FIVE WIPS MAX) LIFT HANDSET, PRESS WIP SELECT SWITCH FOR
REQUIRED WIP, THEN WAIT FOR WARDEN TO ANSWER THE WIP.
(FIVE WIPS MAX) LIFT HANDSET, PRESS WIP SWITCH WITH
FLASHING INDICATOR, INDICATOR WILL GO STEADY.
PRESS WIP SELECT SWITCH WITH STEADY INDICATOR
OR REPLACE HANDSET ON CRADLE.
LIFT HANDSET, PRESS 'ALL CALL' ON MASTER PHONE, WIP
SELECT INDICATORS WILL FLASH, THEN BECOME STEADY AS WIPS
ARE ANSWERED -CONVERSATION IS FROM MASTER TO WIPS ONLY.
REPLACE HANDSET ON CRADLE.
PRESS BUZZER MUTE/ACK
THEN PRESS MASTER RESET TO CANCEL TONES
ALERT SIGNAL
EVACUATION SIGNAL
TO CLEAR SELECTION
THEN RETURN KEYSWITCH TO AUTO.
PRESS P.A. SWITCH
PRESS ALERT SWITCH
PRESS EVAC SWITCH
PRESS CANCEL SWITCH
EMERGENCY CONTROL PANEL
BUZZER
MUTE/ACK
MASTER
RESET
5. WHEN TESTING FIB, PLACE E.W.S. IN MANUAL.
Figure 1: Master Control Panel
EVAC
ALERT
P.A.
CANCEL
ALARM
FAULT
E.W.S.
Figure 2: Occupant Warning System Control Panel
W.I.P.
SELECT
ZONE
CLEARED
FAULT
FAULT
ZONE
CLEARED
W.I.P.
SELECT
E.I.S.
Figure 3: Occupant Intercommunication System Control Panel