STEP TIME
This number specifies the time between steps in 0.01 second (1/100ths of a second). The range of a
step time number is 0 to 255. The longest time between steps therefore, is 2.55 seconds.
To experiment with the tone envelope, type in the following program:
5 ent 1,100,2,2
10 sound 1,284,200,7,0,1
run
Line 10 specifies a sound with a tone period of 284 (interntional a) lasting for 2 seconds with a start
volume of 7, without a volume envelope (represented by 0), and with tone envelope number 1.
Line 5 is tone envelope number 1 consisting of 100 steps, increasing the tone period (reducing the
frequency) by 2 every 0.02 second (2/100ths of a second).
Now change line 5 in each of the following ways and then run each time to hear the effect of
changing the tone envelope:
5 ent 1,100,-2,2
5 ent 1,10,4,20
5 ent 1,10,-4,20
Now replace the sound command and the tone envelope by typing in:
5 ent 1,2,17,70
10 sound 1,142,140,15,0,1
15 goto 5
run
Press the [ESC] key twice to break
Now you can put the volume envelope, tone envelope, and sound command together to create various
sounds. Start by typing in:
new
5 env 1,100,1,3
10 ent 1,100,5,3
20 sound 1,284,300,1,1,1
run
Then replace line 10 by typing in:
10 ent 1,100,-2,3