2011/04 43 EN
OptiBean
7.2 Display messages
7.3 Malfunctions
Problem Possible cause Correction
Out of order boiler filling Boiler is still empty, boiler is not
filling up or is filling up too slowly.
No action required.
Out of order boiler heating The boiler temperature is too low
because too much water is used.
Wait until the boiler temperature
has reached the correct level.
Out of order drip tray full Drip tray is full. Empty drip tray.
Out of order waste bin full Waste bin full Empty waste bins.
Out of order waste bin is miss-
ing
Waste bin is missing. Replace the waste bins.
Out of order door open The door is open. Close the door or use the door
pin.
Out of order stand-by The machine is on standby. Remove the standby mode in the
configuration menu.
Close door The door is not closed correctly. Close the door.
Problem Possible cause Correction
The machine does not work. Broken fuse. Check fuses.
The machine is switched off. Switch on the machine
Broken cable. Check the power cable.
The machine does not
reponse.
The machine is in standby. Switch of fthe standy mode.
Bad product taste. The canister is empty. Fill the canister.
The canister is incorrectly posi-
tioned.
Position the canister correctly.
The outlet of the canister is
blocked.
Clean the outlet of the canister.
The distributor of the canistor
does not work.
Check the distributor of the can-
ister or clean the canister.
Wrong ingredient. Use the correct ingredient.
The ingredient is solidified
(caked).
Replace the ingredient.
The mixer is not cleaned. Clean the mixer.
The ingredient has expired. Replace the ingredient.
The boiler temperature is too low. Contact the dealer or service
engineer.
The ingredient is damp. Check the ventilation system and
replace the ingredient.