Basic Rate Tests Reading Test Results Data
15-16 PN: 13000-00110 Rev. V MT8852B Programming Manual
Enhanced Power Control Test Results
Summary Results
Extension Codes 0 Standard
1 All steps in last cycle
Extension Code: 0
DHx Results valid e.g. TRUE | FALSE
Maximum power of all DHx packets (dBm) e.g. 1.5
Minimum power of all DHx packet (dBm) e.g. –34.6
Maximum DHx step size (dB) e.g. 6.4
Minimum DHx step size (dB) e.g. 2.5
DHx Repeat Max diff (dB) e.g. 0.1
2DHx Results valid e.g. TRUE | FALSE
Maximum power of all 2DHx packets
headers (dBm)
e.g. 1.0
Minimum power of all 2DHx packets
headers (dBm)
e.g. –32.5
Maximum 2DHx step size (dB) e.g. 7.2
Minimum 2DHx step size (dB) e.g. 3.1
2DHx Repeat Max diff (dB) e.g. 0.1
Max 2DHx to DHx diff (dB) e.g. 2.5
3DHx Results valid e.g. TRUE | FALSE
Maximum power of all 3DHx packets
headers (dBm)
e.g. 1.2
Minimum power of all 3Mbps packets
headers (dBm)
e.g. –30.4
Maximum 3DHx step size (dB) e.g. 5.7
Minimum 3DHx step size (dB) e.g. 5.0
3DHx Repeat Max diff (dB) e.g. 0.1
Max 3DHx to DHx diff (dB) e.g. 8.0
Max 2DHx to 3DHx diff (dB) e.g. 5.0
Pass/fail state e.g. PASS | FAIL