EDR Tests Reading Test Results Data
15-38 PN: 13000-00110 Rev. V MT8852B Programming Manual
BER Floor Sensitivity Test Results
(MT8852B and MT8852B-042 only)
Summary Results
Extension Codes 0: Standard
1: Frame Error Details
2: Received Packets errors
Extension Code: 0
2Mbps results Valid e.g. TRUE | FALSE
2Mbps overall BER e.g. 0.00e+000
2Mbps Bits in error e.g. 0
2Mbps packets sent e.g. 4500
2Mbps packets in error e.g. 0
2Mbps Pass or Fail e.g. PASS | FAIL
3Mbps results Valid e.g. TRUE | FALSE
3Mbps overall BER e.g. 1.24e–006
3Mbps Bits in error e.g. 30
3Mbps packets sent e.g. 2970
3Mbps packets in error e.g. 29
3Mbps Pass or Fail e.g. PASS | FAIL
Example:
EFS0,TRUE,0.00e+000,0,4500,0,PASS,TRUE,1.24e-006,30,2970,29,PASS
Extension Code: 1
2Mbps Overall CRC FERs e.g. 0 Returned packet had a changed CRC
2Mbps Overall Length FERs e.g. 0 Returned packet had a different length
2Mbps Overall lost packet FERs e.g. 0 No packet returned or unrecognisable
3Mbps Overall CRC FERs e.g. 28
3Mbps Overall Length FERs e.g. 0
3Mbps Overall lost packet FERs e.g. 1
Example:
EFS1,TRUE,0.00e+000,0,4500,0,PASS,TRUE,1.24e-006,30,2970,29,PASS,
0,0,0,28,0,1
Extension Code: 2
2Mbps Total packets received e.g. 4500
3Mbps Total packets received e.g. 2969
Example:
EFS2,TRUE,0.00e+000,0,4500,0,PASS,TRUE,1.24e-006,30,2970,29,PASS,
0,0,0,28,0,1,4500,2969