EasyManua.ls Logo

Anritsu MT8852B - EDR Sensitivity Test Results

Anritsu MT8852B
309 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Reading Test Results Data EDR Tests
MT8852B Programming Manual PN: 13000-00110 Rev. V 15-35
EDR Sensitivity Test Results
(MT8852B and MT8852B-042 only)
Summary Results
Extension Codes 0: Standard
1: Frame Error Details
2: Received Packets errors
Extension Code: 0
2Mbps results Valid e.g. TRUE | FALSE
2Mbps overall BER e.g. 0.00e+000
2Mbps Bits in error e.g. 0
2Mbps packets sent e.g. 900
2Mbps packets in error e.g. 0
2Mbps Pass or Fail e.g. PASS | FAIL
3Mbps results Valid e.g. TRUE | FALSE
3Mbps overall BER e.g. 3.89e–006
3Mbps Bits in error e.g. 20
3Mbps packets sent e.g. 630
3Mbps packets in error e.g. 23
3Mbps Pass or Fail e.g. PASS | FAIL
Example: EBS0,TRUE,0.00e+000,0,900,0,PASS,TRUE,3.89e-006,20,630,23,PASS
Extension Code: 1
2Mbps Overall CRC FERs e.g. 0 Returned packet had a changed CRC
2Mbps Overall Length FERs e.g. 0 Returned packet had a different length
2Mbps Overall lost packet FERs e.g. 0 No packet returned or unrecognisable
3Mbps Overall CRC FERs e.g. 22
3Mbps Overall Length FERs e.g. 0
3Mbps Overall lost packet FERs e.g. 1
Example:
EBS1,TRUE,0.00e+000,0,900,0,PASS,TRUE,3.89e-006,20,630,23,
PASS,0,0,0,22,0,1
Extension Code: 2
2Mbps Total packets received e.g. 900
3Mbps Total packets received e.g. 629
Example:
EBS2,TRUE,0.00e+000,0,900,0,PASS,TRUE,3.89e-006,20,630,23,PASS,
0,0,0,22,0,1,900,629