18
COUNTER
There are 3 types of counter, general counter, box counter and lot counter.
Each type has 4 parameters, which are max, min, start (current) and step value.
Each counter will reset to its minimum value when current value exceeds its maximum
value. If box counters current value exceeds its max, it will carried to lot number counter.
Ex: General counter: step=1, current:56
0 1 2 3 4 5 6 999
Box: step=10, reset:10010 Lot:step=2,current:46
10 20 30 99 100 2 4 6 8 20
In this example, counters current value changes from (5,100,4) to (6,10,6).
SHIFT
Shift table divides a day into 5 periods, each represent a working shift. Shift object will use
current time to match proper shift name and then print it out.
Ex: Now is 09:14, so the shift name is AAA.
LOGO
Select the logo object for logo list. Besides, we also could use Message Pro to import more
logo sources.
Box# overflow
Lot# carried